Usage: htt_util [options]

options:
 --help
    Show help (this message).

 --device [id]
    Selects the target for the following commands in setups where multiple HTTs
    are connected. (0 = default)

 --loadcalibration [filename]
    Load the calibration data from a file, only available on resistive
    touch screens.

 --rotatetouch [degrees]
    Sets and saves the rotation for the touch panel (visual output will not
    change orientation.) Normally the host OS should take care of screen
    rotation, if the host OS does not support this, this options offers
    the option to apply the rotation on the device
    degrees can be [0, 90, 180, 270]. 
    
 --savecalibration [filename]
    Save the calibration data to a file, only available on resistive touch
    screens.

 --scan
    Scan for HTT modules and display their settings.

 --sensitivity [level]
    Sets the sensitivity of the touch panel.
    This setting is only available on mxt and 7" gt9xx driver based modules.
    Attempting set this option to anything besides 'normal' on any other product
    will lead to undefined behavior and is not recommended.

    level for mxt can be [normal,high,extra]
    level for 7" GT9xx can be [normal,high]


===Following commands are for PCB Rev 1.5 or higher only====

 --backlight [setting]
    set backlight brightness [0-255]

 --backlightfade [time in ms]
    set and save the response time to a backlight brightness change

 --backlightset [setting]
    set and save backlight brightness [0-255]

 --haptic [duration]
	enable haptic feedback for [duration]
    [duration] duration for haptic feedback (in 100ms increments)
    for 1 second - use 10 

 --piezo [duration]
	sound the piezo at 440hz for [duration]
    [duration] duration for piezo (in 100ms increments)
    for 1 second - use 10

 --alarm [type] [duration] [flash]
    The alarm will continue until either one of the folowwing conditions occurs:
	     - The duration of the alarm is reached.
	     - The screen is touched (touch capable models only).
	     - The alarm is canceled by selecting alarm type 0.
    type 0-17 alarm type [0 = off]
    duration duration for the alarm (in 100ms increments, for 1 second - use 10), use -1 for no timeout, the alarm will continue until touch or cancelation.

    flash - flashes per second, max = 10, off = 0

 --touchfeedback
    set touch feedback: [0 none, 1 haptic, 2 piezo, 3 haptic and piezo].

 --touchdim [time1] [brightness1] [time2] [brightness2] [time3] [brightness3] [time4] [brightness4]
    dim the display after [time] seconds of inactivity.
    [time1]       [0-600] time in seconds since last touch
    [brightness1] [0-255] brightness of the display 0 = Off, 255 is full brightness
    [time2]       [0-600] time in seconds since [time1]
    [brightness2] [0-255] brightness of the display 0 = Off, 255 is full brightness
    [time3]       [0-600] time in seconds since [time3]
    [brightness3] [0-255] brightness of the display 0 = Off, 255 is full brightness
    [time4]       [0-600] time in seconds since [time4]
    [brightness4] [0-255] brightness of the display 0 = Off, 255 is full brightness
    to disable feature: --touchdim 0 0 0 0 0 0 0 0
    Note: while time is specified in seconds, for convenience time can be postfixed with the letter 'm' for specify minutes ie 5m would automatically convert to 300 seconds. --capcalibrate 
    PCAP calibrate

 --factorydefaults